THIS PRODUCT IS DISCONTINUED and has been replaced with our Silica Analyzer 9041. The
8241 Silica monitor has been designed with the greatest simplicity
in mind. Developed as continuous monitor offering wide dynamic ranging,
the 8241 features a carefully designed liquid handling section,
which reduces maintenance to an absolute minimum. Cost effective
ownership is insured through the utilization of microprocessor-based
electronics that offer automatic calibration, continuous sample
monitoring and programmable multi-stream switching. |
|
||
| FEATURES | BENEFITS | |
| Programmable Auto Zero Facility | Automatically compensates for sample color and reagent background silica. True auto zero. | |
| Unique Heated Block Assembly | Maintains full temperature control over chemical reactions and optical measurement system. | |
| Fully Programmable Multi-Stream Option | Six stream capability maximizes operational control for monitoring a number of samples from different locations | |
| Dynamic Mixing and Temperature Control | Insures full mixing and reproducible control of samples and reagents guaranteeing complete chemical reaction | |
| Low Maintenance Sample Pump | Annual pump tubing replacement maximizes on-line availability | |
| Microprocessor-Based High Specification Electronics | Controls all measurement and management functions, eliminating operator attention after set-up | |
| Comprehensive Self-Diagnostics | Minimizes operator error and optical source maintenance needs | |
| Continuous Uninterrupted On-Line Measurement Cycle | Insures optimum speed of response |
| INSTALLATION GUIDELINES | ||
| Installation Information: The monitor should be installed where the following conditions can be maintained. | ||
| Sample
flow: 5 to 750ml/min. Suspended
solids: Ambient temperature: |
Sample
temperature: Within the range 5 to 55°C. Reagent solutions: Calibration
solutions: |
|
| GENERAL SPECIFICATIONS | ||
Range: Repeatability: Reproducibility: Response
time: Chemical
drift: Control temperature
range: Temperature
resolution: Degree of
protection: Security
code: |
Current
outputs: SINGLE STREAM OR MULTISTREAM As standard, two isolated current outputs 0 to 1, 0 to 10, 0 to 20, or 4 to 20mA, software selectable. Range independently selectable over the full range of the monitor. Maximum voltage load is 15V. Computer
interface: Alarms: MULTISTREAM Concentration
alarm adjustment: Calibration: Power supply: Isolation
voltage: |
|
Displays: Status indication: |
||